Pots 66 Block

Pots 66 Block Average ratng: 5,0/5 5381 reviews
Block

It is surprising that in the 21st century we are still punching down copper lines! None the less fax machines, credit card devices, postage machines and security circuits still populate the installed base of telephone systems. If you are converting from a legacy phone system to a VoIP solution, on premise or hosted, you will have to plan for “analog” devices. A “best practice” for any VoIP phone system is to have at least one analog telephone company provided central office line, per site, attached for power failure and E911 operation. ShoreTel, for example, has conveniently made it possible for one “port” on a ShoreGear switch to cut through to another port enabling basic POTS operation during a commercial power failure.

Product Title 12-Pack Terra Cotta Pots with Saucer, Mini Small Ter. Average rating: 3.8 out of 5 stars, based on 5 reviews 5 ratings Current Price $20.99 $ 20. 99 List List Price $29.99 $ 29. The venerable 66 type punch down block is typically used to accomplish analog device connectivity. We like to think of the 66 block as the “border controller” in the analog world.

The venerable 66 type punch down block is typically used to accomplish analog device connectivity. We like to think of the 66 block as the “border controller” in the analog world. You can easily separate the telephone company (read WAN) from the customer owned and operated equipment (read LAN) by removing the bridging clip that separates one side of the block from the other. VoIP or not, the 66 block is not going away. Phone technicians love 66 blocks, but IT technicians prefer “patch panels”? Unfortunately, the telephone company typically delivers the circuits at the MPOE or “main point of entry” downstairs in the basement! If you want to get it up to your patch panel, you are going to have to deal with the 66 block.

The basic components are the 66M1-50 split 25 pair block and wall mount bracket. The block is designed to cut down two 25 pair cables on each side of the block using an industry standard color code. Typically you would put your equipment on one side of the block and your station distribution on the other side of the block. Generally “cross connect” pairs act as the equivalent of patch cables, interconnecting equipment and devices. A “bridge” clip is used to connect one side of the block to the other side. If you are thinking ahead, you might use a “rat tail” cable that ends in a male or female amphenol connector to limit punch down and facilitate quick connect.

The ShoreGear switches have a male RJ-21X amphenol connector on the face plate. You will need a female or red amphenol connector to bring 25 pairs of copper out to your 66 block or patch panel. Optionally, 66 blocks can be obtained with an RJ-21X amphenol connector built in. For reasons nobody can explain, the Male connector has a Blue cap and the Female connector has a Red cap over the connector pins for protection. Beware of what sex your connector needs to be!

There is an industry agreed color code and sequence that defines how a 25 pair cable should be punched down. ShoreGear switches, however do not use all pairs. Each switch type has a different port pin out, so pay attention to your planning and installation guide. Additionally, not all analog ports are equal on a ShoreTel switch. There are three types: Universal, Fxo and Fxs so make sure you know what device you are needing to connect and use the correct port type. Universal ports will support either a Central Office line (Fxo) or a Station device (Fxs).

Pots 66 Blocks

The video walks you through the details of connecting a ShoreGear switch to a 66 block, outlines various cable alternatives and details the color code! With the help of our friends at cable supply.com there is a detailed presentation on how to “punch down” a 25 pair cable on a 66 block. Enjoy and as always comments are welcome!

  1. Hello, I think your website might be having browser compatibility issues.
    When I look at your website in Firefox, it looks
    fine but when opening in Internet Explorer, it has some overlapping.
    I just wanted to give you a quick heads up! Other then that, superb blog!

  2. I’m going to bookmark your site for future reference. Keep writing great posts like this!

Leave a Reply

You must be logged in to post a comment.

Pots 66 Block Covers

This site uses Akismet to reduce spam. Learn how your comment data is processed.

A split-50 M or 66 Block with bridging clips
BlockPots

A 66 block is a type of punchdown block used to connect sets of wires in a telephone system. They have been manufactured in three sizes, A, B, and M. A and B have six clips in each row while M has only 4. The A blocks have the rows spaced farther apart and have been obsolete for many years. The B style is used mainly in distribution panels where several destinations (often 1A2 key telephones) need to connect to the same source. The M blocks are often used to connect a single instrument to such a distribution block. 66 blocks are designed to terminate 22 through 26 AWG solid copper wire. The 66 series connecting block, introduced in the Bell System in 1962, was the first terminating device with insulation displacement connector technology. The term 66 block reflects its Western Electric model number.

The 25-pair standard non-split 66 Block contains 50 rows; each row has four (M) or six (B) columns of clips that are electrically bonded. The 25-pair 'Split 50' 66 Block is the industry standard for easy termination of voice cabling, and is a standard network termination by telephone companies–generally on commercial properties. Each row contains four (M) or six (B) clips, but the left two (or three) clips are electrically isolated from the right two (or three) clips. Smaller versions also exist with fewer rows for residential use.

66 blocks are available pre-assembled with an RJ-21 female connector that accepts a quick connection to a 25-pair cable with a male end. These connections are typically made between the block and the customer premises equipment (CPE).

Use[edit]

66 Block B series with 6 clips in each row. Jumper wires on the left connect the top pair with the bottom pair, allowing to split up to 10 devices.

66 Block 12 Pair

Circuit pairs are connected to the block with a punch-down tool by terminating the tip wire on the leftmost slot of one row and ring wire on the leftmost slot of the row beneath the mating tip wire. Typically, a 25-pair cable coming from the phone company is punched down on the left side of the block in pairs. The right hand side of the block is wired to the customer premises equipment with jumper wires. Bridging clips are used to connect the two center terminals, connecting the left-hand side of a split block with its right-hand side, thus completing the circuit. The clips form the point of interface between the subscriber and the provider. The bridging clips can be easily removed by either the subscriber or phone company personnel for trouble isolation, allowing the ability to split a circuit and determine in which direction trouble may exist. An orange insulating cover attached to a 66 block denotes its designation as a demarcation point by the local exchange carrier.

Modern 110 blocks largely supplanted 66 blocks for new commercial installations at the end of the 20th century, as the capability for a circuit to carry digital data overlaid its ability to carry analog voice conversations. 110 block termination is almost always Category 5 (or higher) compliant, and capable of supporting 100 MHz (or faster) signaling. Compared to 110 and higher-density wire terminating blocks, 66 blocks are physically large; and because of their maximum 16 MHz Category 3 signaling compatibility, they are ill-suited for high speed (faster than 10BASE-T) data circuits. However, special Category 5e Certified 66 blocks are available from manufacturers such as Siemon which meet all standards for Cat5e termination.[1]

Split 50 66 blocks are still used as network interface blocks in distribution frames to interconnect circuits with bridging clips, but are primarily limited to narrowband circuits such as POTS/DSL, DS0, or DS1 circuits.

Pots 66 Block

See also[edit]

66 Block Price

References[edit]

Pots 66 Block And Bricks

Retrieved from 'https://en.wikipedia.org/w/index.php?title=66_block&oldid=965700273'